면책 고지: 이 사이트는 FDA, ClinicalTrials.gov, PubMed, SEC EDGAR 등 공식 공개 데이터를 일반 참고용으로 집계하며, 의학적 조언, 진단, 치료 권고 또는 투자 조언이 아닙니다.

임상시험

Breaking Force of Periodontal Suture Materials After Intraoral Exposure

NCT: NCT07852520 · COMPLETED

NCT IDNCT07852520
상태COMPLETED
시작일2025-05-01
완료2025-10-15
SponsorCukurova University (OTHER)
First posted
Last updated

간략 요약

This prospective, six-arm randomized clinical retrieval study was designed to compare the maximum breaking force of three commonly used non-absorbable periodontal suture materials-silk, polypropylene, and polytetrafluoroethylene (PTFE)-in sizes 3-0 and 4-0 before clinical use and after 7 days of intraoral exposure following periodontal flap surgery. The study included 120 participants with Stage III Grade B periodontitis requiring periodontal flap surgery. Participants were randomly allocated in a 1:1:1:1:1:1 ratio to one of six suture material-diameter groups: silk 3-0, silk 4-0, polypropylene 3-0, polypropylene 4-0, PTFE 3-0, or PTFE 4-0. Sutures were retrieved on postoperative day 7 and subjected to laboratory mechanical testing. Maximum breaking force was measured using a universal testing machine and compared with independent unused Day-0 specimens of the corresponding material and diameter. The study aimed to determine the effects of suture material, USP diameter, and exposure condition on maximum breaking force.

공식 출처

ClinicalTrials.gov에서 보기 →

데이터는 ClinicalTrials.gov API에서 제공됩니다. 최신 상태는 공식 기록을 확인하세요.

↑