Volumetric Specimen Imager Device for the Intraoperative Imaging of Patients With Breast Carcinoma and Breast Ductal Carcinoma In Situ, The VIVID Study

NCT: NCT05545150 · COMPLETED

NCT IDNCT05545150
StatusCOMPLETED
Start Date2022-11-28
Completion2025-03-20
SponsorNorthwestern University (OTHER)
First posted
Last updated

Brief Summary

This clinical trial assesses if the use of a three-dimensional imaging device called the Clarix Imaging Volumetric Specimen Imager (VSI) can help guide and assist surgeons in identifying and removing all positive margins while in the operating room (intraoperative imaging) for patients with breast cancer and breast ductal carcinoma in situ. Breast conservation surgery or lumpectomy is a standard of care (routine) procedure that removes the tumor and a rim of surrounding normal tissue (margins) while leaving as much normal breast tissue as possible. A margin that does not contain tumor cells is called a negative margin and tells the surgeon that the primary tumor has been removed. A positive margin contains tumor cells at or near the edge of the tissue removed. As part of standard of care, surgeons take two-dimensional x-ray images of the tissue that has been removed in the operating room to assess if there is any additional tissue that should be shaved (removed) to get a negative margin. After the surgery is over, the tissue is examined once again by a pathologist in a laboratory to determine if there are any small pieces of tumor left in the margin that were not visible during surgery. If residual tumor is detected in the margin, a reoperation may be required to remove additional tissue until the tumor has been completely removed from the margin. Diagnostic procedures, such as intraoperative volumetric specimen imaging may reduce the rate of reoperation of for patients who previously underwent lumpectomy.

Frequently Asked Questions

What is Volumetric Specimen Imager Device for the Intraoperative Imaging of Patients With Breast Carcinoma and Breast Ductal Carcinoma In Situ, The VIVID Study?

Volumetric Specimen Imager Device for the Intraoperative Imaging of Patients With Breast Carcinoma and Breast Ductal Carcinoma In Situ, The VIVID Study is a clinical trial registered under NCT05545150. Current status: COMPLETED.

What is the status of NCT05545150?

The current status of NCT05545150 (Volumetric Specimen Imager Device for the Intraoperative Imaging of Patients With Breast Carcinoma and Breast Ductal Carcinoma In Situ, The VIVID Study) is: COMPLETED.

When did Volumetric Specimen Imager Device for the Intraoperative Imaging of Patients With Breast Carcinoma and Breast Ductal Carcinoma In Situ, The VIVID Study start?

Volumetric Specimen Imager Device for the Intraoperative Imaging of Patients With Breast Carcinoma and Breast Ductal Carcinoma In Situ, The VIVID Study started on 2022-11-28.