Disclaimer: This site aggregates publicly available data from official government sources (FDA, ClinicalTrials.gov, PubMed, SEC EDGAR) for general reference only. It does NOT constitute medical advice, diagnosis, treatment recommendations, or investment advice.

Clinical Trial

Cuffless BP Monitoring in Hemodialysis

NCT: NCT07753876 · ENROLLING_BY_INVITATION

NCT IDNCT07753876
StatusENROLLING_BY_INVITATION
Start Date2025-07-01
Completion2026-09-01
SponsorGangnam Severance Hospital (OTHER)
First posted
Last updated

Brief Summary

This is a prospective, multicenter observational cohort study designed to evaluate the validity and clinical utility of cuffless blood pressure monitoring using the CART BP Pro device in patients receiving maintenance hemodialysis. Blood pressure measured using the CART BP Pro device will be compared with 24-hour ambulatory blood pressure monitoring (ABPM) and conventional pre-dialysis blood pressure measurements to evaluate its validity. The reproducibility of cuffless blood pressure measurements will also be assessed through repeated measurements performed at one-week intervals. In addition, the associations between blood pressure parameters measured using the CART BP Pro device and cardiovascular indicators, including echocardiographic parameters, coronary artery calcium score, body composition measurements, and clinical outcomes, will be prospectively evaluated during a 12-month follow-up period. The study hypothesizes that cuffless blood pressure monitoring using the CART BP Pro device provides valid and reproducible blood pressure measurements in patients receiving maintenance hemodialysis. Furthermore, blood pressure parameters measured using the CART BP Pro device are expected to demonstrate stronger associations with cardiovascular indicators and to provide better prediction of cardiovascular events and all-cause mortality than conventional pre-dialysis blood pressure measurements and 24-hour ambulatory blood pressure monitoring.

Frequently Asked Questions

What is Cuffless BP Monitoring in Hemodialysis?

Cuffless BP Monitoring in Hemodialysis is a clinical trial registered under NCT07753876. Current status: ENROLLING_BY_INVITATION.

What is the status of NCT07753876?

The current status of NCT07753876 (Cuffless BP Monitoring in Hemodialysis) is: ENROLLING_BY_INVITATION.

When did Cuffless BP Monitoring in Hemodialysis start?

Cuffless BP Monitoring in Hemodialysis started on 2025-07-01.

Official Source

View on ClinicalTrials.gov →

Data sourced from ClinicalTrials.gov API. For the most current status, refer to the official record.