Disclaimer: This site aggregates publicly available data from official government sources (FDA, ClinicalTrials.gov, PubMed, SEC EDGAR) for general reference only. It does NOT constitute medical advice, diagnosis, treatment recommendations, or investment advice.

Clinical Trial

Videolaryngoscopes in the Morbidly Obese

NCT: NCT07787468 · ENROLLING_BY_INVITATION

NCT IDNCT07787468
StatusENROLLING_BY_INVITATION
Start Date2026-08-15
Completion2026-11-01
SponsorUniwersytet Radomski im. Kazimierza Pułaskiego (OTHER)
First posted
Last updated

Brief Summary

This study will evaluate four videolaryngoscopes used for intubation of extremely obese (class 3 obesity) patients scheduled for bariatric surgery. One hundred adult patients will be scheduled for an elective sleeve gastrectomy at the Mazowiecki Szpital Specjalistyczny in Radom, Poland. All patients will receive premedication with 300 mg pregabalin 30 minutes before the start of anaesthesia. An extended monitoring will be applied. This consists of ECG, IBP (invasive blood pressure), SpO2, TOF (train-of-four), entropy and volatile anaesthetic concentration. All patients will be placed in a ramped position (HELP - Head-elevated Laryngoscopy Position) and will be pre-oxygenated with FiO2 1.0 for three minutes prior to induction. A standardised local protocol of opioid-free anaesthesia for bariatric patients will be utilised. Prior to proper induction of anaesthesia, IV infusions of 1% lidocaine and dexmedetomidine 10 µg ml-1 will be started. This will be followed by induction with IV propofol (200 mg) and ketamine (50 mg). Rocuronium (100 mg) will be used as a neuromuscular blocking agent. Adequate neuromuscular block will be confirmed and controlled throughout the procedure with TOF Watch (Organon, Dublin, Ireland). A cuffed, size 8.0 tracheal tube with stylet (Sumi, Sulejówek, Poland) will be used for intubation. A single-use hyperangulated blade will be used in all studied devices. Correct placement of the tracheal tube will be confirmed by videolaryngoscopy, capnography and chest auscultation. All patients will be anaesthetised by experienced consultant anaesthetists with over 10 years of clinical practice after completion of specialist training. Furthermore, all anaesthetists participating in the study will be trained with all VLs used until they feel competent. Only two intubation attempts with a studied videolaryngoscope will be allowed. A single attempt will be limited to 60 seconds. A failure is defined as an attempt which lasted more than 60 seconds, when saturation dropped below 90%, after two unsuccessful attempts, when airway injury or bronchospasm occurred. A single-digit number will be allocated to each of the studied videolaryngoscopes: 1 for the C-MAC PM, 2 for the McGrath MAC, 3 for the VisionPro and 4 for the AceScope. A single sheet of paper containing printed number will be placed in an opaque envelope. Then they will be assigned to the participating anaesthetist by computer-generated randomization. The SPSS 29.0 software (IBM, Armonk, NY, USA) will be used for allocation. Furthermore, patients will be blinded to randomization.

Frequently Asked Questions

What is Videolaryngoscopes in the Morbidly Obese?

Videolaryngoscopes in the Morbidly Obese is a clinical trial registered under NCT07787468. Current status: ENROLLING_BY_INVITATION.

What is the status of NCT07787468?

The current status of NCT07787468 (Videolaryngoscopes in the Morbidly Obese) is: ENROLLING_BY_INVITATION.

When did Videolaryngoscopes in the Morbidly Obese start?

Videolaryngoscopes in the Morbidly Obese started on 2026-08-15.

Related Devices

K250243ProVu Single Use Video Stylet with Reinforced ET Tube (Size 6.5) (038-995-065U); ProVu Single Use Video Stylet with Reinforced ET Tube (Size 7.0) (038-995-070U); ProVu Single Use Video Stylet with Reinforced ET Tube (Size 7.5) (038-995-075U); ProVu Single Use Video Stylet with Reinforced ET Tube (Size 8.0) (038-995-080U)Flexicare Medical Limited. K243785Shiley™ Oral/Nasal Tracheal Tube with TaperGuard™ Cuff Reinforced, Murphy Eye Shiley™ Tracheal Tube TaperGuard™ Cuff Reinforced with Stylet Shiley™ Lo-Contour Oral/Nasal Tracheal Tube Cuffed Reinforced Shiley™ Lo-Contour Oral/Nasal Tracheal Tube Cuffed Reinforced, Murphy Eye Shiley™ Oral/Nasal Tracheal Tube Cuffless ReinforcedCovidien, LLC K213234CARESCAPE ONE and CARESCAPE DOCK F0, Model Numbers MBZ323 and MFA101, CARESCAPE ECG, Model Number MKE101,CARESCAPE TEMP, Model Number MKT101, CARESCAPE PRES, Model Number MKP101, CARESCAPE SPO2, Model Numbers MKS101 and MKS201Ge Medical Systems Information Technologies, Inc. K162768ECG multi leads and IP-SET trunk cable, Monobloc ECG cable, SpO2 sensors and IBP transducers interface cable, ECG leadwire for INTEGRAL PROCESS trunk cables, ECG leadwire for original truk cablesIntegral Process Sas K250173Shiley™ Oral RAE Tracheal Tube Cuffless, Murphy Eye (113-XX) Shiley™ Nasal RAE Tracheal Tube Cuffless, Murphy Eye (114-XX) Shiley™ Oral RAE Tracheal Tube Cuffed, Murphy Eye (115-XX) Shiley™ Oral RAE Tracheal Tube with TaperGuard™ Cuff, Murphy Eye (115-XXOR) Shiley™ Nasal RAE Tracheal Tube with TaperGuard™ Cuff, Murphy Eye (119-XXNR)Covidien, LLC

Official Source

View on ClinicalTrials.gov →

Data sourced from ClinicalTrials.gov API. For the most current status, refer to the official record.