免責聲明: 本站彙整 FDA、ClinicalTrials.gov、PubMed、SEC EDGAR 等官方公開資料,僅供一般參考,不構成醫療建議、診斷、治療建議或投資建議。

臨床試驗

The Effect of Compression Stockings and Leg Elevation on Hemodynamic Stability in Elective Cesarean Sections Under Spinal Anesthesia: A Single-Blind Randomized Controlled Trial

NCT:NCT07534891 · COMPLETED

NCT IDNCT07534891
狀態COMPLETED
開始日期2023-11-01
完成時間2025-02-20

簡要摘要

Aim: This study aimed to evaluate the effects of compression stockings and leg elevation on maternal intraoperative hypotension, vasopressor requirement, and neonatal well-being parameters in women undergoing elective cesarean section spinal anesthesia. Methods: This single-blind randomized controlled experimental study was conducted in the obstetrics service and operating room of Afşin State Hospital between November 1, 2023, and February 20, 2025. A total of 90 pregnant women who met the inclusion criteria were randomly assigned into three groups: the compression stockings group (n=30), the leg elevation group (n=30), and the control group (n=30). Spinal anesthesia was administered to all participants according to a standardized protocol. Maternal systolic, diastolic, and mean arterial blood pressure, as well as heart rate, were monitored at regular intervals during the intraoperative period. The occurrence of hypotension, vasopressor use, and side effects such as nausea and vomiting were recorded. Neonatal outcomes included the 5-minute APGAR score and umbilical venous blood gas parameters (pH and base excess). Data were analyzed using appropriate statistical methods. Results: Intraoperative systolic, diastolic, and mean arterial blood pressure values were significantly higher in both the compression stockings and leg elevation groups compared to the control group (p\<0.05). The rate of vasopressor use was significantly lower in both intervention groups compared to the control group (p\<0.05). There were no statistically significant differences among the groups in terms of neonatal APGAR scores, umbilical venous pH, and base excess values (p\>0.05). Conclusion: The use of compression stockings and leg elevation in women undergoing elective cesarean section تحت spinal anesthesia are effective, safe, and feasible non-pharmacological methods for maintaining maternal hemodynamic stability. These interventions reduce vasopressor requirements and hypotension-related side effects without adversely affecting short-term neonatal outcomes. The findings suggest that these methods can be integrated into clinical nursing practice for the prevention of spinal anesthesia-induced hypotension.

官方來源

在 ClinicalTrials.gov 上查看 →

資料來自 ClinicalTrials.gov API。最新狀態請參閱官方紀錄。

↑