Avertissement: Ce site agrège des données publiques officielles provenant de la FDA, ClinicalTrials.gov, PubMed et SEC EDGAR à titre de référence générale uniquement. Il ne constitue pas un avis médical, un diagnostic, une recommandation de traitement ni un conseil en investissement.

Essai clinique

Effect of Adding Silicon Dioxide (SiO₂) Nanoparticles to a Printable Acrylic Resin Denture Base

NCT : NCT07817420 · COMPLETED

ID NCTNCT07817420
StatutCOMPLETED
Date de début2023-02-01
Achèvement2025-09-10
SponsorMansoura University (OTHER)
First posted
Last updated

Résumé succinct

This clinical study evaluated whether adding a small amount (0.5 wt%) of silicon dioxide (SiO₂) nanoparticles to a 3D-printable acrylic denture material could improve the clinical performance of implant-retained mandibular overdentures. the results showed that the SiO₂-modified denture bases had smoother surfaces and were associated with better peri-implant soft tissue measurements than the conventional 3D-printed denture bases. The modified denture bases also showed lower bacterial counts and reduced Candida albicans levels during follow-up. No implant failures were reported during the study period.

Source officielle

Voir sur ClinicalTrials.gov →

Données issues de l’API ClinicalTrials.gov. Pour connaître le statut le plus récent, consultez la fiche officielle.

↑